Version: 1.6.1
Date: 26-6-2011
Requires server: 1.3.107d USB usbs13107d.exe
File name: BM2_1-6-1.BM2
Languages: Danish, Dutch, English, French, German, Italian, Norwegian, Swedish, Spanish, Turkish, Chinese
New:
Players can enter hand records on the Bridgemate at the end of the round.
Players can view hand records on the Bridgemate of a board after its result has been entered and confirmed.
New option 7 in TD-menu to view hand records.
Show names directly after numbers are entered (before start of round 1), and possibility to correct numbers.
Possibility to erase all previous entered data (scores and member numbers) when a Bridgemate takes over another table.
Improved method of erasing scores from TD-menu (doesn't ask for round anymore, unless needed).
Score verification screen shows score in NS or EW column (when American result method is selected).
Scores erased from TD-menu or score recap are now also removed from the Bridgemate's internal memory.
Bugs fixed:
viewing the ranking and end-of-game summary could distort the internal backup of scores entered on the Bridgemate.
----------------------------------------------------------
Version 1.5.5 Date: 7-3-2011
Requires: Bridgemate II USB Server firmware version 1.3.101d
New:
- End-of-game summary added
- Ranking after each round - or - only at end of session added.
- Score recap may automatically display (at the end of each round) - option setting in BCS.
- Improved alignment of all result lists.
Version 1.4.2 Date: 25-9-2010
Requires: Bridgemate II USB Server firmware version 1.3.1d
New:
SCAN mode can find and work with sections from multiple servers.
When a Bridgemate takes over another Bridgemate, a message appears on the original Bridgemate that it has been removed from its table.
In the round information screen, seating information shown at the previous end-of-round screen can be retrieved again by pressing the BACK key.
Bridgemate responds to any key when blinking verification by East message is shown.
Bugs fixed:
Sections are not properly displayed in SCAN mode when more than 63 sections are used.
Overview of results was not suppressed when the score was automatically accepted by the Bridgemate.
Scores resent from the SETUP menu could contain a "wrong direction" indication.
Version 1.3.1 Date: 13-7-2010
Requires: Bridgemate II USB Server firmware version 1.2.1d or 1.2.2d
New:
Names display feature added.
Names are shown as soon as they are available in the server.
Bridgemate II display screen - auto Contrast feature added.
Travelers - including 'oiptional" lead card - can be shown.
Member number validation according to ACBL algorithm.
Recording (bids and play) feature added.
Bug fixed: Bridgemates could sometimes skip one round.
Version 1.0.6 Date: 15-2-2010
Requires: Bridgemate II Server firmware version 1.0.10d
New:
Bridgemate can force another table to log off and take over its position when the other table has logged on as the wrong table number.
Data is locally stored in the Bridgemate II EEPROM and can be sent to the server using Score resend.
"Score resend" functionality added to TD Menu and Setup to resend scores to the server at any time.
The actual Section / Table number (of the data being transmitted) is displayed when using SETUP —› Info —› Resend (scores).
Bridgemate status stored during data entry. Bridgemate will return to "saved-status point" after battery loss.
SCAN function automatically displays the current section when the game has only 1 section. (Note: In a multi-section game, the one-section
default may be encountered when a Bridgemate logs on too early - before the subsequent sections have been loaded into the server.)
Results can be erased from the current or any previous round using TD-Menu #3. Note: With ACBLscore score corrections must be made
at the Bridgemate before the score has been posted into ACBLscore.
"Scores" Function key remains during the full "end of round" screen.
After erasing a result (using TD-Menu, pin code and #3), the board number is automatically confirmed and the new result can be entered directly.
"RESET" function key can be enabled/disabled (for player use) through the Bridgemate II options screen.
The Bridgemate's Section/Table is shown in the TD Pin code entry screen.
Cancel key can be used during the blinking "Verification by East or West" screen to cancel North's input.
Score recap can also be accessed from the TD-Menu #6. (Useful when the "scores" option is not enabled for players.)
Board result will now be stored in Bridgemate's memory when the transmission to the server fails.
Change: Bridgemate will now go into standby when displaying "Failed to send data, retry?" - instead of staying alive and trying to resend the score every 20 seconds.
Bug Fix: Score recap showed random scores when the last round was not played and score-recap was accessed from the End-of-Session screen.
Bridgemate USB Server Firmware
Bridgemate II systems
Version 1.3.101d Date: 1-3-2011
Requires
Bridgemate II terminal firmware version 1.5.1
New: Added ranking and end-of-game summary feature.
Version 1.3.1d Date: 25-9-2010
Requires
Bridgemate II terminal firmware version 1.4.2
New:
Bridgemate SCAN mode can retrieve sections from multiple servers.
When a Bridgemate logs on as a new section/table combination without being correctly logged off from the server (usually this never happens, only when communication between server and Bridgemate is unreliable), the Bridgemate's old section/table reference is removed from the server to allow the new logon to be successful.
Bug fixed. Conditions where server would "freeze" and/or clear its own data memory have been corrected.
Version 1.2.2d Date: 13-8-2010 Requires
Bridgemate II terminal firmware version 1.3.1
New:
Show names feature added.
Names are shown as soon as they are available in the server.
Travelers - including 'optional' lead card - can be shown on Bridgemates II
Member number validation according to ACBL algorithm.
Israel Region added.
Bugs fixed:
Bridgemates could sometimes skip one round.
Server firmware could sometimes lock up or reset itself.
|
|